Measurement range: (0 - 1500) ppm
Maximum allowable error: ±30 ppm or ±5% (display value)
Repeatability: ≤3%
Span and zero drift: ±3%F.S
Response time: < 60
In industrial fields such as power, metallurgy, and petrochemical, the safe use of SF6 gas is directly related to production safety and efficiency. To monitor SF6 gas leakage in real time and accurately, and respond promptly to potential safety hazards, we specifically introduce the SF6 Gas Leakage Online Monitoring System. This system integrates real-time monitoring, intelligent alarm, and fan linkage, providing a new guarantee for your safe production.
Analysis of the Product's Core Highlights
Real-time Monitoring, Precise Data Transmission over Long Distances
The SF6 Gas Leakage Online Monitoring System accurately transmits real-time measurement information such as SF6, oxygen, temperature, and humidity on-site to the DCS via the RS - 485 bus. This function ensures that you can keep abreast of the on-site gas conditions at any time, providing strong support for safe production.
Intelligent Alarm, Quick Fan Linkage
When the monitored data exceeds the set alarm value, the system will immediately activate the audible and visual alarm or exhaust equipment, achieving intelligent alarm and fan linkage. This design can quickly eliminate potential safety hazards and ensure on-site safety.
Human Infrared Monitoring, Automatic Exhaust Protection
The system is equipped with a human infrared monitoring function. When a human body is detected, the fan will automatically start for exhaust. The exhaust time can be set in the fan parameters as required, ensuring that the SF6 gas has been effectively removed before workers enter the work area, thus protecting the safety of workers.
Ultra-long Life Sensor, Precise Detection Guarantee
An imported SF6 gas infrared sensor with an ultra-long service life is used to ensure the accuracy and reliability of the detection results. This feature provides a solid guarantee for safe production and reduces the risks caused by gas leakage.
Multi-functional Components, Flexible Configuration to Meet Requirements
The system supports functional components such as optional human infrared detectors, voice prompts, audible and visual alarms, and linked fans. You can configure them flexibly according to actual needs to meet the monitoring requirements in different scenarios, improving the system's applicability and practicality.
Support for Multiple Monitoring Points, Convenient Data Transmission and Output over Long Distances
The SF6 Gas Leakage Online Monitoring System supports the detection, display, recording, and alarm of up to 64 monitoring points. At the same time, it also supports the long-distance transmission and output of measurement data through RS - 485, facilitating your data management and analysis and improving work efficiency.
Application Scenarios and Significance
The SF6 Gas Leakage Online Monitoring System is widely applicable to occasions where SF6 gas is used, such as GIS electrical switches, transformers, and electrical busbars in the power industry, metallurgy industry, and petrochemical industry. Its real-time monitoring and intelligent alarm functions can greatly reduce the risk of SF6 gas leakage, ensure on-site safe production, create greater value for your enterprise, and improve the level of safe production.
Choosing the SF6 Gas Leakage Online Monitoring System means choosing the perfect combination of real-time monitoring, intelligent linkage, and safe production. Let's work together to use the power of technology to ensure the safe use of SF6 gas and contribute to the safe production and efficiency improvement of enterprises!
Product Parameters
Parameters of NA1000MR Multi-channel Alarm Controller
Parameter Name | Parameter Value |
---|---|
Display Screen | TFT256 color |
Transmission Interface | RS-485 bus |
Transmission Distance | ≤1000m |
Connection Method | RVVP 4×0.75mm² shielded cable bus type |
Input Quantity | (1~64) channels of intelligent transmitters |
Operating Voltage | (85~265) VAC, 50/60Hz |
Ambient Temperature | (-30~60)°C |
Ambient Humidity | (0~95)%RH (no condensation) |
Installation Method | wall-mounted |
Dimensions | 440mm×330mm×140mm (L×W×H) |
Weight | 10kg |
Parameters of NA1000FDII Gas Detection Alarm Instrument
Parameter Name | Parameter Value |
---|---|
Sulfur Hexafluoride (SF₆) - Measurement Range | (0~1500) ppm |
Sulfur Hexafluoride (SF₆) - Maximum Allowable Error | ±30ppm or ±5% (display value) |
Sulfur Hexafluoride (SF₆) - Repeatability | ≤3% |
Sulfur Hexafluoride (SF₆) - Range and Zero Drift | ±3%F.S |
Sulfur Hexafluoride (SF₆) - Response Time | <60s |
Oxygen (O₂) - Measurement Range | (0~25)% |
Oxygen (O₂) - Maximum Allowable Error | ±0.5% (volume ratio) |
Oxygen (O₂) - Repeatability | ≤1% |
Oxygen (O₂) - Range and Zero Drift | ±1%F.S |
Oxygen (O₂) - Response Time | <60s |
Temperature - Measurement Range | (-40~100)°C |
Temperature - Maximum Allowable Error | ±2℃ |
Humidity - Measurement Range | (0~99)%RH |
Humidity - Maximum Allowable Error | ±5%RH |